Less operations and better readable
This commit is contained in:
parent
81e70925c4
commit
e00e778bce
@ -126,8 +126,8 @@ class UsermodBattery : public Usermod
|
||||
if (pinManager.allocatePin(batteryPin, false, PinOwner::UM_Battery)) {
|
||||
DEBUG_PRINTLN(F("Battery pin allocation succeeded."));
|
||||
success = true;
|
||||
//initialize voltage again with analog read as that will give us faster precision
|
||||
voltage = (analogReadMilliVolts(batteryPin) / 1000.0f + calibration / 2.0f) * 2.0f;
|
||||
//initialize voltage with analog read
|
||||
voltage = analogReadMilliVolts(batteryPin) / 500.0f + calibration;
|
||||
}
|
||||
|
||||
if (!success) {
|
||||
@ -179,12 +179,10 @@ class UsermodBattery : public Usermod
|
||||
initializing = false;
|
||||
|
||||
#ifdef ARDUINO_ARCH_ESP32
|
||||
// use calibrated millivolts analogread on esp32 (150 mV ~ 2450 mV)
|
||||
rawValue = analogReadMilliVolts(batteryPin) / 1000.0f + calibration / 2.0f;
|
||||
// calculate the voltage with a 1/20th weighted running average
|
||||
voltage = ((voltage / 2.0f) * 19.0f + rawValue) / 20.0f;
|
||||
// usually a voltage divider (50%) is used on ESP32, so we need to multiply by 2
|
||||
voltage *= 2.0f;
|
||||
// use calibrated millivolts analogread on esp32 (150 mV ~ 2450 mV) and divide by 500 to fix to the right decimal place and multiply by 2 to account for the voltage divider
|
||||
rawValue = analogReadMilliVolts(batteryPin) / 500.0f + calibration;
|
||||
// calculate the voltage with a weighted running average because ADC in ESP32 is fluctuating too much for a good single readout
|
||||
voltage = (voltage * 19.0f + rawValue) / 20.0f;
|
||||
#else
|
||||
// read battery raw input
|
||||
rawValue = analogRead(batteryPin);
|
||||
@ -192,7 +190,7 @@ class UsermodBattery : public Usermod
|
||||
// calculate the voltage
|
||||
voltage = ((rawValue / getAdcPrecision()) * maxBatteryVoltage) + calibration;
|
||||
#endif
|
||||
// check if voltage is within specified voltage range, allow 10% over/under voltage
|
||||
// check if voltage is within specified voltage range, allow 10% over/under voltage - removed cause this just makes it hard for people to troubleshoot as the voltage in the web gui will say invalid instead of displaying a voltage
|
||||
//voltage = ((voltage < minBatteryVoltage * 0.85f) || (voltage > maxBatteryVoltage * 1.1f)) ? -1.0f : voltage;
|
||||
|
||||
// translate battery voltage into percentage
|
||||
|
Loading…