Commit Graph

1245 Commits

Author SHA1 Message Date
Aircoookie
99b1282e98
Merge pull request #1317 from jsloyer/patch-1
correct the copyright year and add a link to the license
2020-11-10 13:47:56 +01:00
cschwinne
ed753b590c Add copyright and license link to .htm 2020-11-10 13:30:42 +01:00
Aircoookie
bda095b0ec
Merge pull request #1325 from e850205/patch-1
Update readme.md
2020-11-10 13:27:12 +01:00
cschwinne
9d7f1d230c Only add 16 to macros if they are not 0 2020-11-09 20:48:44 +01:00
e850205
bdf0458780
Update readme.md 2020-11-09 13:14:24 -06:00
cschwinne
7f973ad131 Unaccessible wsec.json and preset loading fix 2020-11-09 11:09:47 +01:00
cschwinne
1f42070104 A few fixes 2020-11-09 00:50:13 +01:00
cschwinne
98e4ac6b27 FS working for ESP8266 2020-11-08 23:44:10 +01:00
Chris AtLee
8d318e7206 Return remaining nightlight time in json API
This returns the number of seconds remaining in the nightlight in the
"rem" field of the nightlight ("nl") state. If there is no nightlight
active, it returns -1.
2020-11-08 10:44:25 -05:00
cschwinne
362156c8ab F() 2020-11-07 23:54:56 +01:00
cschwinne
3ff23ade8b Done in principle 2020-11-06 22:12:48 +01:00
cschwinne
d9050dd8b9 Progress with parsers 2020-11-05 22:54:13 +01:00
Jeff Sloyer
bcee2c37d7
correct the copyright year and add a link to the license 2020-11-05 14:54:57 -05:00
cschwinne
b8fcab29ac Inversed Rain direction (fixes #1147) 2020-11-04 23:20:34 +01:00
cschwinne
8ddae6bba0 wsec start 2020-11-04 17:17:54 +01:00
cschwinne
fc9255cdc4 Added new file for JSON cfg parsing code 2020-11-04 11:04:40 +01:00
cschwinne
f725506df0 Settings deserialization 2020-11-03 00:35:04 +01:00
cschwinne
aa27b85538 Re added old C9 palette 2020-11-01 20:54:35 +01:00
Aircoookie
afe75f8a89
Merge pull request #1309 from herm/usermod_mqtt_switch
Usermod mqtt switch
2020-11-01 20:29:50 +01:00
Hermann Kraus
b725d66ee3 Add options for inverted switches and default values. 2020-11-01 18:08:30 +01:00
Hermann Kraus
fe3fb622ee New usermod: MQTT switches.
This user mod adds a function to toggle output pins via MQTT.
2020-11-01 16:27:23 +01:00
Aircoookie
e8bd114c01
Merge pull request #1307 from herm/mqtt_topic
Fix MQTT topic parsing.
2020-11-01 12:13:21 +01:00
Hermann Kraus
b694bcf62a Fix MQTT topic parsing.
The previous code only looked for certain keywords in the topic instead of comparing it completely.
For example if mqttDeviceTopic is set to "lights/colorRGB" the MQTT interface is unusable because
the search for "/col" will always return a match and therefore any MQTT command is interpreted as
a color.
The new code checks the full topic.
2020-11-01 02:23:37 +01:00
Aircoookie
b0f933c926
Merge pull request #1306 from Aircoookie/master
Update FS branch (yes, it is necessary)
2020-10-31 23:53:29 +01:00
Lech Perczak
2d12bc01de
Change SP501A -> SP501E build configuration (#1305)
Fix a typo in previous commit. Correct board name is SP501E.

Signed-off-by: Lech Perczak <lech.perczak@gmail.com>
2020-10-31 23:51:52 +01:00
Lech Perczak
17b4ff7a1f
Add build configuration for SP501A controller (#1303)
This controller uses ESP8285 with 2MB built-in flash.
Features:
- LED string is connected to GPIO3,
- On/off button connected to GPIO1,
- Built-in transistors to drive non-addressable R-G-B-Wc-Ww strips
  (by default not connected, only pads are present).

Signed-off-by: Lech Perczak <lech.perczak@gmail.com>
2020-10-31 21:41:44 +01:00
Aircoookie
6aff9f91d5
Merge pull request #1304 from Aircoookie/mergefs-201031
Update FS branch (again)
2020-10-31 21:33:59 +01:00
Aircoookie
cac8fd93e4
Merge branch 'filesystem' into mergefs-201031 2020-10-31 21:21:32 +01:00
Miha Frangež
f046abefbc
Mention analog strips in README (#1297) 2020-10-29 20:29:15 +01:00
Aircoookie
b34e060b17
Merge pull request #1287 from huksley/html-es6
Use html-minifer-terser for ES6+ support
2020-10-29 16:59:43 +01:00
cschwinne
907be77ef4 Include minified JS 2020-10-29 10:14:21 +01:00
cschwinne
373d12be64 Realtime max. brightness now honors brightness factor (fixes #1271)
- Colorful effect now supports palettes
- Added C9 2 palette (#1291)
- Improved C9 palette brightness by 12%
- Disable onboard LED if LEDs are off (PR #1245)
- Added optional status LED (PR #1264)
- Realtime max. brightness now honors brightness factor (fixes #1271)
- Updated ArduinoJSON to 6.17.0
2020-10-29 01:23:04 +01:00
Ruslan Gainutdinov
bf45d55b4a Use html-minifer-terser for ES6+ support 2020-10-26 23:31:35 +02:00
cschwinne
2525429070 deEEP for presets 2020-10-23 17:48:01 +02:00
Aircoookie
2513bcf2c6
Merge pull request #1270 from Aircoookie/mergefs-201019
Update FS branch
2020-10-19 23:37:29 +02:00
Aircoookie
bbffb6d901
Merge branch 'filesystem' into mergefs-201019 2020-10-19 23:37:18 +02:00
cschwinne
3b7f5a1397 Merge branch 'master' of https://github.com/Aircoookie/WLED 2020-10-19 23:30:07 +02:00
cschwinne
600e949628 Update ArduinoJson-v6.h 2020-10-19 23:30:02 +02:00
Jeff Rescignano
235c123ad0
Add status led (#1264)
* Add status led

* Shorten code

* Fix "Shorten code"

* Change ledStatusType to an unsigned short
2020-10-19 18:08:45 +02:00
guilhermebera
dcea584a9a
Update readme.md (#1257) 2020-10-17 12:13:41 +02:00
cschwinne
d583adb958 New quota calculation 2020-10-16 23:59:34 +02:00
Aircoookie
0d96a0fb7c
Merge pull request #1255 from guilhermebera/patch-1
Update usermod_PIR_sensor_switch.h
2020-10-14 13:58:38 +02:00
guilhermebera
fb6b2cbfa2
Update usermod_PIR_sensor_switch.h
Current: If I disable PIR after it switch strip on, it'll switch off by timer.
Update: If I disable PIR after it switch strip on, it'll keep strip on.
2020-10-14 01:07:20 -03:00
cschwinne
eb65eafbe0 Working API commands 2020-10-13 01:39:34 +02:00
Jeff Rescignano
13f18492ad
Disable onboard LED when LEDs are not in use (#1245)
* Disable onboard LED when LEDs are not in use

* Remove unused variable

* Only disable onboard LED if LEDPIN == LED_BUILTIN

* Change LEDPIN to LED_BUILTIN
2020-10-12 20:13:13 +02:00
Aircoookie
3d04541ee3
Merge pull request #1239 from rawframe/patch-1
Usermod PIR with Highlight & Standby modes and more control. (branched from Gegus PIR_sensor_switch)
2020-10-09 15:51:31 +02:00
Jeff Rescignano
6ded0cce12
[ImgBot] Optimize images (#1238)
*Total -- 2,546.93kb -> 2,358.92kb (7.38%)

/images/wled_logo_clean.png -- 2.48kb -> 0.59kb (76.3%)
/usermods/Enclosure_with_OLED_temp_ESP07/assets/pcb.png -- 235.03kb -> 201.10kb (14.43%)
/images/wled_logo.png -- 46.43kb -> 40.20kb (13.41%)
/images/wled_logo_akemi.png -- 24.41kb -> 21.60kb (11.5%)
/usermods/TTGO-T-Display/assets/ttgo_hardware1.png -- 685.48kb -> 613.17kb (10.55%)
/usermods/Enclosure_with_OLED_temp_ESP07/assets/controller.jpg -- 149.82kb -> 136.31kb (9.02%)
/usermods/battery_keypad_controller/assets/bat-key-ctrl-1.jpg -- 318.82kb -> 298.56kb (6.36%)
/usermods/battery_keypad_controller/assets/bat-key-ctrl-3.jpg -- 343.93kb -> 322.75kb (6.16%)
/usermods/battery_keypad_controller/assets/bat-key-ctrl-2.jpg -- 250.06kb -> 235.49kb (5.83%)
/images/macbook-pro-space-gray-on-the-wooden-table.jpg -- 490.48kb -> 489.15kb (0.27%)

Signed-off-by: ImgBotApp <ImgBotHelp@gmail.com>

Co-authored-by: ImgBotApp <ImgBotHelp@gmail.com>
2020-10-09 12:48:19 +02:00
rawframe
1ecbaf2c7f
Create PIR_Highlight_Standby
* Rawframe edit:
 * - TESTED ON WLED VS.0.10.1 - WHERE ONLY PRESET 16 SAVES SEGMENTS - some macros may not be needed if this changes.
 * - Code has been modified as my usage changed, as such it has poor use of functions vs if thens, but feel free to change it for me :)
 * 
 * Edited to SWITCH between two lighting scenes/modes : STANDBY and HIGHLIGHT
 * 
 * Usage:
 *  - Standby is the default mode and Highlight is activated when the PIR detects activity.
 *  - PIR delay now set to same value as Nightlight feature on boot but otherwise controlled as normal.
 *  - Standby and Highlight brightness can be set on the fly (default values set on boot via macros calling presets).
 *  - Macros are used to set Standby and Highlight states (macros can load saved presets etc).
 * 
 *    - Macro short button press   =  Highlight state default (used on boot only and sets default brightness).
 *    - Macro double button press  =  Standby state default   (used on boot only and sets default brightness).
 *    - Macro long button press    =  Highlight state         (after boot).
 *    - Macro 16                   =  Standby state           (after boot).
 *
 *    ! It is advised not to set 'Apply preset at boot' or a boot macro (that activates a preset) as we will call our own macros on boot.
 * 
 *  - When the strip is off before PIR activates the strip will return to off for Standby mode, and vice versa.
 *  - When the strip is turned off while in Highlight mode, it will return to standby mode. (This behaviour could be changed easily if for some reason you wanted the lights to go out when the pir is activated).
 *  - Macros can be chained so you could do almost anything, such as have standby mode also turn on the nightlight function with a new time delay.
 * 
 * Segment Notes:
 * - It's easier to save the segment selections in preset than apply via macro while we a limited to preset 16. (Ie, instead of selecting sections at the point of activating standby/highlight modes). 
 * - Because only preset 16 saves segments, for now we are having to use additional macros to control segments where they are involved. Macros can be chained so this works but it would be better if macros also accepted json-api commands. (Testing http api segment behaviour of SS with SB left me a little confused).
 * 
 * Future:
 *  - Maybe a second timer/timetable that turns on/off standby mode also after set inactivity period / date & times. For now this can be achieved others ways so may not be worth eating more processing power.
2020-10-08 23:42:32 +01:00
cschwinne
b0828a6280 Bigger buffer testing 2020-10-08 00:52:15 +02:00
cschwinne
d2ffb3ca9d FQ quota and info 2020-10-07 17:48:22 +02:00