# Temperature usermod
|
|
|
|
Based on the excellent `QuinLED_Dig_Uno_Temp_MQTT` by srg74 and 400killer!
|
|
This usermod will read from an attached DS18B20 temperature sensor (as available on the QuinLED Dig-Uno)
|
|
The temperature is displayed both in the Info section of the web UI as well as published to the `/temperature` MQTT topic if enabled.
|
|
This usermod will be expanded with support for different sensor types in the future.
|
|
|
|
If temperature sensor is not detected during boot, this usermod will be disabled.
|
|
|
|
## Installation
|
|
|
|
Copy the example `platformio_override.ini` to the root directory. This file should be placed in the same directory as `platformio.ini`.
|
|
|
|
### Define Your Options
|
|
|
|
* `USERMOD_DALLASTEMPERATURE` - define this to have this user mod included wled00\usermods_list.cpp
|
|
* `USERMOD_DALLASTEMPERATURE_FIRST_MEASUREMENT_AT` - the number of milliseconds after boot to take first measurement, defaults to 20 seconds
|
|
|
|
All parameters can be configured at runtime using Usermods settings page.
|
|
|
|
## Project link
|
|
|
|
* [QuinLED-Dig-Uno](https://quinled.info/2018/09/15/quinled-dig-uno/) - Project link
|
|
|
|
### PlatformIO requirements
|
|
|
|
If you are using `platformio_override.ini`, you should be able to refresh the task list and see your custom task, for example `env:d1_mini_usermod_dallas_temperature_C`.
|
|
|
|
|
|
If you are not using `platformio_override.ini`, you might have to uncomment `DallasTemperature@~3.8.0`,`OneWire@~2.3.5 under` `[common]` section in `platformio.ini`:
|
|
|
|
```ini
|
|
# platformio.ini
|
|
...
|
|
[platformio]
|
|
...
|
|
; default_envs = esp07
|
|
default_envs = d1_mini
|
|
...
|
|
[common]
|
|
...
|
|
lib_deps =
|
|
...
|
|
#For Dallas sensor uncomment following 2 lines
|
|
DallasTemperature@~3.8.0
|
|
OneWire@~2.3.5
|
|
...
|
|
```
|
|
|
|
## Change Log
|
|
|
|
2020-09-12
|
|
* Changed to use async, non-blocking implementation
|
|
* Do not report low temperatures that indicate an error to mqtt
|
|
* Disable plugin if temperature sensor not detected
|
|
* Report the number of seconds until the first read in the info screen instead of sensor error
|
|
2021-04
|
|
* Adaptation for runtime configuration. |